Roof Enclosure For Shaft Wall

Flat Roof Screen Pool Enclosure To Fit Your Homes Design Designed Installed By Dreamwork Aluminum This Desi Fort Myers Pool Screen Enclosure House Exterior

Flat Roof Screen Pool Enclosure To Fit Your Homes Design Designed Installed By Dreamwork Aluminum This Desi Fort Myers Pool Screen Enclosure House Exterior

Spandrel Wall Download Details Concrete Deck Mineral Wool Design

Spandrel Wall Download Details Concrete Deck Mineral Wool Design

Curtain Wall Roof Connection With Gutter In 2020 Curtain Wall Curtain Wall Detail Roof Detail

Curtain Wall Roof Connection With Gutter In 2020 Curtain Wall Curtain Wall Detail Roof Detail

Lightweight Framing Timber Frame Construction Framing Construction Wood Frame Construction

Lightweight Framing Timber Frame Construction Framing Construction Wood Frame Construction

Residential Timber Framed Construction Timber Frame Construction Framing Construction Wood Frame Construction

Residential Timber Framed Construction Timber Frame Construction Framing Construction Wood Frame Construction

Pin On Ideas For The House

Pin On Ideas For The House

Pin On Ideas For The House

Shaft enclosure for hvac ductwork and roof drain pipes extends from ground floor slab up through the roof of a 2 story building.

Roof enclosure for shaft wall.

Ul design u499 w419. However because shaft enclosure walls are to be constructed as fire barriers per section 713 2 many shaft wall requirements directly reference provisions on fire barriers found in section 707. Below the roof the shaft enclosure has a 2 hour rating. 1 hour corridor ceiling assembly with single layer 5 8 gypsum panels.

Solid shafts horizontal stud shafts. Shaftwall system consists of 1 shaftliner panels supported by 2 1 2 4 or 6 c t studs and faced on one side with two layers of 1 2 fire code board. Installation detail for transition to rated vertical shaft xl009 23 installation detail for transition to rated horizontal shaft xl015 24 installation detail for grease hoods xl022 25 optimized grease duct enclosure system 26 installation pictures good installations and bad access door examples 27. Shaft enclosures are specifi cally addressed in ibc section 713.

These shafts are vital for vertical communication power water fresh air exhaust and a means of egress. Shaft enclosures are specifically addressed in section 713 of the 2015 international building code ibc. Solid shafts are normally used to construct mechanical or duct enclosures or in areas where a small section of shaft wall is needed for a single vertical pipe penetration. However because shaft enclosure walls are to be constructed as fi re barriers per section 713 2 many shaft wall require ments directly reference provisions of fi re barriers found in section 707.

Shaft enclosures that are permitted to be penetrated by ducts and air transfer openings shall be protected with approved fire and smoke dampers installed in accordance with their listing. Stairwall systems are designed to enclose stairwalls this system is finished on both sides with a single layer of 1 2 fire code board. Head of wall firestop system elastomeric spray firestop. Sw 104 1 hour shaftwall to steel deck.

Diagram Of Wall Assembly Enclosures Wall Design

Diagram Of Wall Assembly Enclosures Wall Design

Pin On Conrect

Pin On Conrect

Wood Frame House Section Drawings Google Search Timber Frame Construction Framing Construction Wood Frame Construction

Wood Frame House Section Drawings Google Search Timber Frame Construction Framing Construction Wood Frame Construction

Enclosure Details Baum Architecture Construction Details Architecture Brick Architecture Brick Construction

Enclosure Details Baum Architecture Construction Details Architecture Brick Architecture Brick Construction

Source : pinterest.com