Osha 1910 29 b contains system requirements that employers must follow to ensure guardrail systems will protect workers from falling to lower levels.
Roof edge guardrail requirements.
The top edge height may exceed 45 inches 114 cm provided the guardrail system meets all other criteria of paragraph b of this section see figure d 11 below.
The guard shall extend not less than 30.
Conventional fall protection guardrail fall restraint or fall arrest system is required.
6 feet from the edge.
The top edge height may exceed 45 inches 1 14 m provided the guardrail system meets all other criteria of paragraph b of this section.
Osha requires that workers exposed to a fall hazard must have fall protection.
Top edge height of top rails or equivalent guardrail system members shall be 42 inches 1 1 m plus or minus 3 inches 8 cm above the walking working level.
When conditions warrant the height of the top edge may exceed the 45 inch height provided the guardrail system meets all other criteria of this paragraph.
Required guards shall be not less than 42 inches 1 07m high measured vertically as follows.
From the adjacent walking surfaces.
Industry standard says that protection must be in place for anyone working within 15 feet of the roof edge.
The 1926 standard doesn t make specific mention to distance from roof edge but again states that for roofing work on low slope roofs with unprotected sides and edges 6 feet 1 8 m or more above lower levels shall be protected from falling by guardrail systems safety net systems personal fall arrest systems or a combination of those systems.
The top edge height may exceed 45 inches 114 cm provided the guardrail system meets all other criteria of paragraph b of this section see figure d 11 of this section.
In addition the code continues to specifically address fall protection near mechanical equipment which is where the edge accufit safety railing was being placed to protect requirements stating guards shall be provided where various components that require service are located within 10 feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches 762mm above the floor roof or grade below.
Conventional fall protection guardrail fall restraint or fall arrest system is required.
The top edge height of top rails or equivalent guardrail system members are 42 inches 107 cm plus or minus 3 inches 8 cm above the walking working surface.
Guards shall be provided where appliance equipment fans roof hatch openings or other components that require service are located within 10 feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches above floor roof or grade below.
Each roof railing system is designed by a sales engineer to ensure the highest level of safety.
1910 29 b 1 the top edge height of top rails or equivalent guardrail system members are 42 inches 107 cm plus or minus 3 inches 8 cm above the walking working surface.
Keeguard roof railing exceeds this requirement and has the testing documents to prove it.
Between 6 feet and 15 feet from the edge.